Sprinkler recommendations from your insurer: what to do after a risk survey

The survey report lands a few weeks after the visit.

Somewhere inside is a numbered list of recommendations, and at least one mentions the sprinkler system. It might ask for a full service, a repair to a valve set, an investigation into the water supply or protection for an area that has none. Each item comes with a deadline and, often, a link to your cover or premium.

Sprinkler insurance requirements can feel vague until you read them closely. Most recommendations come back to the same few points. The system should be designed to a recognised standard, installed and maintained by an approved contractor, and backed by paperwork that proves it. This guide explains what insurers usually ask for, what the common recommendations mean and how to close them out without wasted spend.

Why insurers focus on sprinkler systems

Sprinklers change the size of a likely loss more than almost any other fire precaution. A working system controls a fire while it is still small, so insurers price and accept risks partly on whether that system will perform when it is needed.

That is why a surveyor looks well past the heads on the ceiling. They want to see an adequate water supply, valves that are open and secured, a design that still suits what the building stores today, and testing records that are up to date.

The standards insurers measure against

In the UK, most insurers judge sprinkler systems against the LPC Rules for Automatic Sprinkler Installations. Published by the Fire Protection Association, the LPC Rules combine BS EN 12845 with a set of technical bulletins that reflect UK insurer experience and loss data. Systems designed to an older standard, or altered over the years without reference to the rules, are a frequent source of recommendations.

There is a legal side too. Article 17 of the Regulatory Reform (Fire Safety) Order 2005 requires fire safety equipment to be kept in efficient working order. An insurer’s maintenance recommendation usually overlaps with a duty you already carry.

Common sprinkler recommendations and what they mean

Survey reports vary between insurers, but certain items appear again and again.

Service and testing out of date

This is the most common finding by some distance. The insurer wants evidence of routine checks by site staff and periodic servicing by a competent contractor, all recorded in the system log book. The rules set out weekly checks on alarm valves and pumps, followed by a schedule of quarterly, half yearly and annual inspections.

Gaps usually happen when a site changes facilities manager or contractor and the routine quietly lapses. Getting back on track normally means a full service visit, followed by a booked programme for the year ahead.

Change of occupancy or storage

Racking gets taller, stock becomes more combustible, or a unit changes tenant. The original design may no longer match the hazard below it. The insurer will often ask for a hydraulic review, and sometimes a redesign, carried out by an approved contractor to confirm the system can still cope.

This recommendation catches many warehouse and logistics sites in particular, where storage layouts shift faster than anyone updates the fire strategy.

Water supply and pump problems

Tank levels, pump performance and town mains pressure all decide whether the system delivers enough water to the heads that open. Recommendations here often ask for a flow test, pump repairs or a fuller investigation where test results have dropped over time. Our fire pumps team handles this work directly.

Impairments and closed valves

A closed or unsecured valve is one of the most common reasons sprinklers fail in a real fire. Insurers will ask for main valves to be strapped and padlocked open, monitored where possible, and for any planned shutdown to be reported to them before work begins.

Why your choice of contractor affects sign off

Most insurers expect sprinkler work to be carried out by a contractor certified under LPS 1048, the Loss Prevention Certification Board scheme for sprinkler installers. The certificate of conformity issued at the end of a job gives the insurer independent evidence that the work meets the rules.

Before appointing anyone, check their status on RedBookLive, where you can search LPCB certified installers and confirm a certificate is current. Our guide to LPS 1048 approved contractors explains the approval levels in more detail. Using an uncertified firm can leave the recommendation open, which means paying twice to have the work checked or repeated.

What insurers expect to see on file

A surveyor’s visit goes much faster when the paperwork is ready. Most will ask to see the same core documents, and having them in one place often heads off recommendations before they are written.

  • The original design certificate or certificate of conformity for the installation
  • The system log book, showing weekly tests signed off by site staff
  • Service reports from the last 12 months, including any defects raised
  • Records of impairments, with dates the system was out of action and when it was restored
  • Details of any changes to storage, layout or occupancy since the last survey

If any of these are missing, a contractor can usually rebuild the picture through a full inspection. That gives you a fresh baseline to show the next surveyor, and a clear list of anything that needs fixing.

Closing out a recommendation without delay

A clear process saves time and money:

  1. Note the deadline. Recommendations usually carry a date, and missing it can affect your cover. If you need longer, speak to your broker early and share the plan.
  2. Get the system surveyed. A competent engineer should compare each recommendation against what is actually installed, since some items are quick fixes and others need design work.
  3. Ask for a written quote that references each recommendation number. This makes it simple for the insurer to match the work to their report.
  4. Keep every piece of evidence. Service reports, test certificates, photographs and any certificate of conformity should go back to your broker as proof of completion.

Sites often find that several recommendations can be cleared in a single visit once the contractor sees the whole report at once, rather than one item at a time.

Get your sprinkler recommendations closed out with Thor Fire

An insurer’s sprinkler recommendation is usually very fixable. The work becomes far easier to plan once you know what the surveyor measures against, who can sign it off and what evidence they expect back.

Thor Fire is an LPS 1048 approved fire sprinkler contractor working across the North West, North Wales, Merseyside and the Midlands. Send us your survey report and we will explain what each sprinkler recommendation involves, what it is likely to cost and how quickly it can be closed. Call 0161 339 7736 or contact the team online.